in Russianin Englishin Finnish

AutoLog® GSM-RTU
Esittely | GSM-4 | GSM-8 | GSM-16 | GSM-20 | GSM Gateway |

AutoLog® GSM Gateway

SER1:
DEFAULT: Integrated GSM/GPRS modem

SER2:
DEFAULT: Modbus RTU master/slave (RS232)
OPT1: Modbus RTU master/slave (RS485)
OPT2: Modbus TCP maste/slave (Ethernet)
OPT3: Wireless Sensor Master Module (ALWSN24-PiM-MM) (Wi-Fi)

Connect your device(s) to GSM network!

View data and make controls using HMI, SCADA, GSM phone or Internet browser!

modbus to gsm DATASHEET GSM Gateway

AutoLog® Modbus to GSM Gateway connects Modbus devices to GSM network. It has all the same features as other AutoLog GSM-RTU devices, but without I/O.

AutoLog Modbus to GSM Gateway read/writes data from Field device(s) using Modbus RTU or Modbus TCP protocol or it can be equipped with Wireless Sensor Master Module (AL WSN24-PiM-MM). The collected data can be logged into Modbus to GSM Gateway’s memory.

AutoLog Modbus to GSM Gateway uses GSM/GPRS network for bidirectional communication with SCADA systems. FF-Automation’s AutoLog ControlMan SCADA can be used to view measurement trends, alarms, process pictures, reports etc. and to send controls, set points etc. Alarms can be forwarded to GSM phones.

AutoLog Modbus to GSM Gateway is programmable device as all AutoLog GSM-RTUs. It can make intelligent Clock/Calendar or events based controls, calculations etc. It is remotely programmable.

Serial ports 1 free serial port
(other serial port is used by integrated GSM modem)
Serial port 1 Integrated GSM/GPRS modem
Serial port 2 Modbus RTU master/slave (RS232/RS485*) or Modbus TCP (ETH)* or Wireless Sensor Master Module* (ALWSN24-PiM-MM)
GSM communication SMS and GPRS
I2C port 1 pcs (HMI, iButton etc.)
PID 32 Build-in
Time controls clock & calendar based
Data logging GSM PLC can save time-stamped measurement or any data into its memory (FTP file = file which can be send using GPRS FTP). FTP file: e.g. 1x 43000 or 4x 21000 or 8x 13000 Time-stamped records
Communication SMS, GPRS, Modbus RTU M/S
Programming Remotely through GSM network or locally using a cable
SCADA / Control room connection Through GSM/GPRS network:
- AutoLog® ControlMan -service OR
- Web Studio SCADA
Enclosure IP20 DIN-rail model
plastic IP65 (Unit models)
Size (h x w x d) 170 x 170 x 80 mm (Unit)
Operating temperature -30°C...+65°C
Storage temperature -40°C...+80°C
Programming tool (PC) AutoLog® GSMProgrammer
Program instructions / functions Logical compare (<>=), basic calculations (+,-,*,/,modulo), IF-THEN clauses, clock- and calendar controls, PID controllers, incoming phone number identification, password identification, free of charge call controls, data logging, etc.
Clock/Calendar Yes (can be set remotely)
GSM/GPRS modem Integrated GSM/GPRS modem and driver.
GSM networks 900/1800MHz or 850MHz/1900MHz or Thuraya Satellite
Power supply 12- 30VDC or 12-24VAC or (Unit models 230VAC) max. 5VA
UPS / lead acid battery Optional, ask more !
EMC Immunity according to EN50082-1 & EN50082-2
Emissions according to EN50081-1 & EN50081-2

* RS-485 , Modbus TCP Ethernet or Wireless sensor network needs optional AutoLog® Plug-in module (PiM)

Order information:

AutoLog® GSM-GW
Order Code 900666
Enclosure Steel case, IP20, DIN-rail installation
Size (w x h x d) 160 X 125 X 65 mm
Weight ~0,3 kg
GSM/GPRS modem Yes, build-in
Power supply 12-30VDC or 12-24VAC, max. 5VA
HMI user interface No (Optional for I2C port)

AutoLog® GSM-GW Unit

Order code 900667
Enclosure Plastic, IP65
Size (w x h x d) 180 x 175 x 80 mm
Weight ~0,7 kg
GSM/GPRS modem Yes, build-in
Power supply 230VAC or 12-30VDC or 12-24VAC,
max. 5VA
HMI user interface No (Optional for I2C port!)

AutoLog® GSM-GW Unit & HMI
Order code 900668
Enclosure Plastic, IP65
Size (w x h x d) 180 x 175 x 80 mm
Weight ~0,7 kg
GSM/GPRS modem Yes, build-in
Power supply 230VAC or 12-30VDC or 12-24VAC,
max. 5VA
HMI user interface Yes, AL1093F cover mounted model. Uses I2C port.


Optional modules and accessories:
SCADA, control room software Web Studio SCADA or AutoLog® ControlMan GSM Web SCADA service Look Web Studio!
AutoLog® ControlMan ControlMan, Web supervision and control service for GSM-RTUs. Look Control-Man!
HMI interfaces
(I2C -port connection)
AL1093F External model (2 x 16 characters)
AL1095A External model (8 x 21 characters / 128 x 64 pixels)
900860
900850
AutoLog®
GSMProgrammer
PC based AutoLog® GSM-RTU programming tool 941020
RS232/485 PiM RS232/485 converter, Plug-in module
(PiM = Plug-in Module)
901165
RS232/485 PiM Iso RS232/485 converter, Plug-in Module, Isolated 901157
Modbus TCP PiM ModbusRTU to ModbusTCP (Ethernet) protocol gateway, Plug-in Module 900065
AL WSN24-PiM-MM Wireless Wi-Fi I/O master Plug in Module. Look accessories
Radio modem External radio modem for wireless communicating and also remote programming of PLC. Look accessories

Note! Same module can be offered with PLC or GSM-PLC system program, if you don't need GSM modem you can use PLC system program.