RTU & PLC
-
Gsm e-SCADA service
-
SCADA
-
HMI & Touch screens
-
Accessories
-
Custom products
|
AutoLog® GSM - 16
Build-in GSM/GPRS modem. One free serial port (other serial port is used by modem), which supports AutoLog® Serial Plug-in modules.
DATASHEET_GSM-16
AutoLog® GSM-RTU devices are designed especially to be used in applications where GSM/GPRS communication is needed. Programming is made very easy; build-in GSM/GPRS driver handles all the complex GSM communication tasks automatically so user can concentrate on application programming. AutoLog® GSM-RTU can be programmed locally using a cable or remotely through GSM network using PC based programming tool or just GSM phone. GSM-PLC has many programming features that are useful in creating GSM applications, like incoming phone number identification etc.
| Analog inputs (AI)** |
0-8 pcs**
Analog input modules, Pt100, KTY10, 0-5V, 0-10V, 0-20mA, 4-20mA, RMS, etc. |
| Digital inputs (DI) |
4 pcs
12/24 VDC / max. 8 mA / PNP / opto-isolated |
| Relay outputs (RO) |
4 pcs
12-24 VDC / max. 2A , 24-230 VAC |
| Serial ports |
1 free serial port
(other serial port is used by integrated GSM modem)
SER2: RS232/485*, supports AutoLog® Plug-in Modules (PiM). |
| GSM/GPRS modem |
Integrated GSM/GPRS modem and driver. |
| GSM/SMS communication |
GSM-RTU use SMS -messages to communicate bidirectionally with SCADA, GSM phone or other GSM-RTUs. SMS -messages can be used to transfer measurement reports and logs, alarms, events, controls, settings, acknowledging and remote programming of GSM-RTU. |
| GPRS/FTP communication |
GSM-RTU use GPRS/FTP for sending measurement reports and logs to SCADA. |
| Call controls |
Special controls can be made using free of charge incoming call phone number identification. |
| Modbus RTU -communication |
Modbus can be used in free serial port (SER2) to connect GSM-RTU with other Modbus devices. e.g. SCADA, PLCs or other intelligent devices like electricity meters.
Master/Slave, 300-115200bps |
| I2C-port |
1 pcs
HMI, iButton, etc. |
| HMI -user interface |
Local user interface can be connected through I2C-port or serial port. Variety of different models from small, character displays to multi-featured Windows CE based graphical touchscreens, with Web Studio SCADA development tool support. Look more from AutoLog® HMI -pages. |
| SCADA / Control room connection |
Through GSM/GPRS network:
- AutoLog® ControlMan -service OR
- Web Studio SCADA |
| Battery backup for Flash |
Yes |
| Application program capacity |
(FLASH), 256 programming lines, one line is 160 characters and can handle many commands. In addition it has 240 numbers memory for incoming phone number identification and 256 table rows for time controls and 256 -iButton identification. |
| Programming tool (PC) |
AutoLog® GSMProgrammer |
| Program instructions / functions |
Logical compare (<>=), basic calculations (+,-,*,/,modulo), IF-THEN clauses, clock- and calendar controls, PID controllers, incoming phone number identification, password identification, free of charge call controls, data logging, etc. |
| PID controllers |
32 build-in PID controllers |
| Remote programming |
Programming can be made locally using a cable or remotely through GSM network using programming AutoLog® GSMProgrammer or just GSM phone. |
| Data memory RAM |
512kB |
| Data logging |
GSM PLC can save time-stamped measurement or any data into its memory (FTP file = file which can be send using GPRS FTP).
FTP file: e.g. 1x 43000 or 4x 21000 or 8x 13000 Time-stamped records
|
| Clock/Calendar |
Yes (can be set remotely) |
| GSM/GPRS modem |
Integrated GSM/GPRS modem and driver. |
| GSM networks |
900/1800MHz or 850MHz/1900MHz or Thuraya Satellite |
| Enclosure |
Default: DIN -rail mounting with metal cover, IP20
Opt 2 : plastic box, IP65
Opt 3: metal box. Ask more! |
| Size (w x h x d) |
220 x 125 x 65 mm |
| Weight |
~0,3 kg |
| Operating temperature |
-30...+65 °C |
| Storage temperature |
-40...+80 °C |
| Power supply |
12- 30VDC or 12-24VAC or (Unit models 230VAC) max. 5VA |
| UPS / lead acid battery |
Optional, ask more ! |
| EMC |
Immunity according to EN50082-1 & EN50082-2
Emissions according to EN50081-1 & EN50081-2 |
* RS-485 , Modbus TCP Ethernet or Wireless sensor network needs optional AutoLog® Plug-in module (PiM)
(**) = Analog input modules are NOT included to GSM UNITS by default! So by default all GSM products have no analog inputs. Analog input modules are small modules which are attached to GSM board with plug in connector. The reason for this is that user can select just the right analog input module combination that is needed. E.g. (0-8) means that GSM board supports maximum of 8 analog input modules. Look the list of available analog inputs modules bellow or ask more.
Order information:
AutoLog® GSM- 16
| Order Code |
900501 |
 |
| Enclosure |
Aluminium case, DIN-rail installation |
| Size (w x h x d) |
220 X 125 X 65 mm |
| Weight |
~0,3 kg |
| GSM/GPRS modem |
Yes, build-in |
| GSM antenna |
Yes, stubby with no cable. Optional 0.3m and 2.5m cable avalilable for other antenna types. |
| Analog input modules |
Optional, ordered separately! |
| Power supply |
12- 30VDC or 12-24VAC |
AutoLog® GSM- 16 Unit
| Order code |
900480 |
|
| Enclosure |
Plastic, IP65 |
| Size |
ask! |
| Weight |
~0,8 kg |
| GSM/GPRS modem |
Yes, build-in |
| GSM antenna |
Yes, stubby with no cable. Optional 0.3m and 2.5m cable avalilable for other antenna types. |
| Power supply |
12- 30VDC or 12-24VAC or (Unit models 230VAC) max. 5VA |
| UPS lead acid battery |
Optional, (12VDC/1.8Ah can be installed inside the enclosure) |
| Analog input modules |
Optional, ordered separately! |
| HMI user interface |
No |
AutoLog® GSM- 16 Unit & HMI
| Order code |
980480 |
|
| Enclosure |
Plastic, IP65 |
| Size |
ask! |
| Weight |
~0,8 kg |
| GSM/GPRS modem |
Yes, build-in |
| GSM antenna |
Yes, stubby with no cable. Optional 0.3m and 2.5m cable avalilable for other antenna types. |
| UPS lead acid battery |
Optional, (12VDC/1.8Ah can be installed inside the enclosure) |
| Power supply |
12- 30VDC or 12-24VAC or 230VAC,
max. 5VA |
| Analog input modules |
Optional, ordered separately! |
| HMI user intrerface |
Yes, AL1093F cover mounted model. Uses I2C port. |
Optional modules and accessories:
| AutoLog® ControlMan |
AutoLog ControlMan is easy to use and maintain supervision and control service for GSM-RTUs. |
Look Control-Man! |
| SCADA, control room software |
Web Studio SCADA or AutoLog® ControlMan |
Look Web Studio! |
Analog input modules
|
Pt100 ( -50..150°C )
Pt100 ( 0..500°C )
Pt100 ( -250..750°C )
0..5mA
0..20mA
4..20mA,
KTY10 (50..150°C),
NTC (-5..50°C),
0..2V,
0..5V,
0..10V,
-10..10V,
RMS 40VAC
RMS 25VAC
RMS 0.25VAC
ask more! |
900781
900782
900784
900795
900799
900800
900797
900796
900788
900785
900786
900790
900809
900807
900808 |
Touchscreens
(reserves serial port connection) |
Look AutoLog HMIs! Windowsc CE based touchscreens.
(Supports Web Studio SCADA development tools) |
|
HMI interfaces
(I2C -port connection) |
Note! By default 1093F is mounted to Unit&HMI models cover!
External model AL1093F (2 x 16 characters)
External model AL1095A (8 x 21 characters / 128 x 64 pixels) |
900860
900850 |
AutoLog®
GSMProgrammer |
PC based AutoLog® GSM-RTU programming tool |
941020 |
| AL RS485 PiM, not isolated |
RS232/485 converter, On board Plug-in module
(PiM = Plug-in Module). reserves one serial port. |
901165 |
| AL RS485 PiM, Isolated |
RS232/485 converter, Isolated. On board Plug-in module
(PiM = Plug-in Module). reserves one serial port. |
901157 |
| AL Modbus TCP PiM |
Modbus RTU to Modbus TCP (Ethernet) protocol gateway. On board Plug-in module (PiM = Plug-in Module). reserves one serial port. |
900065 |
AL WSN24 PiM MM
(Wireless I/O) |
Wireless Wi-Fi I/O master module, ask more! |
981340 |
| Radio modem |
External radio modem for wireless communicating and also remote programming of PLC. |
ask |
Please call or e-mail to get more information!
FF-Automation
Eräkuja 2
01600 Vantaa
Finland
Tel: +358 9 530 6310
Fax: +358 9 530 63130

|