RTU & PLC
-
Gsm e-SCADA service
-
SCADA
-
HMI & Touch screens
-
Accessories
-
Custom products
|
AutoLog® 2000S
AutoLog® PLC is designed for large size projects where large quantity of I/Os are needed. Modular, freely selectable plug-in I/O modules are inserted into metal rack. CPU card and power is also inserted into same rack. CPU card doesn't have own I/O. P-model CPU has build-in power, so it can be used in small MR3 rack.
| CPU module |
CPU2000S
CPU2000P, 24VDC, used in MR-mini kehikossa. |
| Digital inputs (DI) |
(0) 16 - 256 pcs
24 VDC, 230VDC/AC max. 8 mA |
| Digital outputs (DO) |
(0) 16 - 256 pcs
24 VDC / max. 1A, 230V / max 4A |
| Analog inputs (AI) |
(0) 16 - 256 pcs
PT100, KTY10, 0(4)...20mA, 0...5V, 0...10V, etc.. Input range can be programmed pointwise using configuration software. |
| Analog outputs (AO) |
(0) 16 - 256 pcs
0..20mA, 4..20mA, 0..5V / 0..10V |
| Serial ports |
3 pcs
SER1 : RS232
SER2 : RS232
SER3: RS485 (isolated) |
| Modbus RTU -communication |
Modbus can run simultaneously in all serial ports. Independent setting for all serial ports,
Master/Slave, 300-115200bps |
| I2C-port |
1 pcs
HMI, iButton, etc. |
| HMI -user interface |
Local user interface can be connected through I2C-port or serial port. Variety of different models from small, character dislays to multi-featured Windows CE based graphical touchscreens, with Web Studio SCADA development tool support. Look more from AutoLog® HMI -pages. |
| Battery backup |
Yes |
| Application program capacity |
8000 programming lines |
| Program instructions / functions |
Over 260 instructions / functions
Logical, arithmetic, comparison, timer/counter, sequence program, reporting, queue, FIFO, PID... |
| PID controllers |
8 build-in PID controllers |
| Programming tool (PC) |
(AutoLog®) ALProWin, instruction list & ladder, symbolic names, trends, monitoring tables, binary and Modbus programming. |
| Remote programming |
PLCs can be programmed remotely through any transmission media, which supports Modbus protocol. e.g. Radio Network, GSM Data, RS-485. |
| Clock/Calendar |
Yes (can be set remotely) |
| UPS connector |
Yes, using AL-UPS card |
| GSM/GPRS modem |
Optional external GSM/GPRS modem. |
| Enclosure |
metal rack, look mounting racks for more info. |
| Operating temperature** |
0...+55 °C |
| Storage temperature** |
-40...+70 °C |
| Power supply |
24VDC, 110/230VAC VAC max.100VA |
| EMC |
Immunity according to EN50082-1 & EN50082-2
Emissions according to EN50081-1 & EN50081-2 |
Order information:
AutoLog® 2000S/P CPU, I/O cards, Mounting racks, Powers
| product name |
description |
code |
| AL2000S (CPU) |
AutoLog® 2000S CPU card |
902200 |
| AL2000P (CPU) |
AutoLog® 2000P CPU card (for MR3-mini) |
902206 |
AutoLog® 2000 Mounting Racks
| MR-mini |
Mounting Rack for 3 I/O cards, needs P-type CPU card. |
902158 |
| MR-mini (with covers) |
Mounting Rack for 3 I/O cards with covers, needs P-type CPU card. |
902159 |
| MR3 |
Mounting Rack for 3 I/O cards (115 VAC) |
902151 |
| MR3 |
Mounting Rack for 3 I/O cards (220 VAC) |
902152 |
| MR3 |
Mounting Rack for 3 I/O cards (24 VDC) |
902153 |
| MR5 |
Mounting Rack for 5 I/O cards |
902150 |
| MR11 |
Mounting Rack for 11 I/O cards |
902154 |
| MR16 |
Mounting Rack for 16 I/O cards |
902156 |
Expansion cables
FC50, FC100 |
Extra I/O expansion rack can be connected using expansion cable.
Flat cable 50cm and 100cm |
902100
902110 |
AutoLog® 2000: I/O cards
Digital input cards (DI)
| DIC32DC |
32 pcs inputs, 24VDC, max. 8mA, isolated in groups of 16 inputs. |
902220 |
| DIC32AC |
32 pcs inputs, 24VAC, max. 8mA, isolated in groups of 16 inputs. |
902224 |
| DIF16 |
16 pcs inputs, 24VDC, automatic failure indication |
902228 |
Digital output cards (DO)
| DOC32EP/FP |
32 pcs outputs, 24...40VDC/VAC, max. 1A, FET type outputs can be connected parallel. EP -model has electrical protection, FP-model has fuze protection. |
902240
902244 |
| ROC16K |
16 pcs relay outputs, 24...250VAC, max. 4A, pointwise isolation. |
902260 |
| OOC16 |
16 pcs relay outputs, 24...250VAC, 0.6A solid-state outputs, pointwise isolation |
902264 |
| DOF16 |
16 pcs outputs, 24VDC, automatic failure indication |
902248 |
Digital input/output cards (DIO)
| DIO32 |
16 pcs inputs, 24VDC, max. 8mA, isolation in groups of 16 inputs.
16 pcs outputs, 24...40VDC/VAC, max. 1A, FET type outputs can be connected parallel. Electrical protection. |
902266 |
Analog input cards (AI)
| AIC8 |
8 - 16 pcs inputs, 0..480mV, 0..20mA, 4..20mA, 0..5V, 0..10V, Pt100, KTY10. Input type and range in defined pointwise using AlProWin program. |
902273 |
| TIC8 |
Termocouple input, 8 inputs (B, E, K, J, R, S, T), Input type and range in defined pointwise using AlProWin program. Group isolation. |
902274 |
| MIC16 |
16 pcs current inputs, 0..20mA OR 4..20mA. Pointwise isolation. |
902272 |
Analog output cards (AO)
| MOC16 |
16 pcs current outputs, 0..20mA OR 4..20mA. Pointwise isolation. |
902277 |
Analog input/output cards (AIO)
| AIO74 |
7-14 pcs inputs, 0..480mV, 0..20mA, 4..20mA, 0..5V, 0..10V, Pt100, KTY10. Input type and range in defined pointwise using AlProWin program.
4 pcs outputs, 0..20mA OR 4..20mA. Group isolation. |
902270 |
Optional modules and accessories:
| SCADA, control room software |
Web Studio / any SCADA on market that supports Modbus ( 99% of SCADAs support Modbus RTU protocol). |
Look Web Studio! |
Touchscreens
(serial port connection) |
AL57CE-HMI (WinCE 5.7" SNT QVGA)
AL121CE-HMI (WinCE 12.1" TFT SVGA)
(Supports Web Studio SCADA development tools) |
945122
945124
|
HMI interfaces
(I2C -port connection) |
AL1093F (2 x 16 characters)
AL1095A (8 x 21 characters / 128 x 64 pixels) |
900860
900850 |
| ALProWin |
PC based AutoLog® PLC programming tool |
941020 |
| Radio modem |
External radio modem for wireless communicating and also remote programming of PLC. |
ask |
| GSM modem |
External GSM modem, look also GSM-20 model if you need GSM modem! |
ask |
Please call or e-mail to get more information!
FF-Automation
Eräkuja 2
01600 Vantaa
Finland
Tel: +358 9 530 6310
Fax: +358 9 530 63130

|